Leveraging ultrasonic distance detection, EM400-UDL ensures a stable and reliable performance while detecting different solid or liquid mediums. Featuring non-contact distance measurement, the probe of EM400-UDL will remain unaffected or contaminated by the medium detected, and deliver highly accurate measurement.
EM400-UDL comes in three versions Standard, Pro and Snow Level versions with different probes optional. With 5 probes at choice, EM400-UDL provides great flexibility to satisfy various demands for professional applications.

IP67 rated enclosure ensures EM400-UDL is protected against dust, water, and other environmental hazards, enabling it to withstand harsh environment.
EM400-UDL also features a conformal coating on its PCBA, which provides an extra layer of protection against moisture, dust, and other contaminants that can damage electronic components.
These two features extend the lifespan of the EM400-UDL and ensure that it continues to function reliably in harsh conditions.
Switching On/Off & Configuring the Devices Wirelessly

Install the
Milesight ToolBox

Enable NFC and run ToolBox,
then attach your phone to the device

Verify the password
and start configuring
Distance
Range
Standard Version= C050: 25 ~ 500 cm C100: 25 ~ 1000 cm
Pro Version= W050: 30 ~ 500 cm W100: 50 ~ 1000 cm
Snow Version= S050: 50 ~ 500 cm
Accuracy
Standard Version= ± (1+0.3%*S) cm1, S=distance
Pro Version= ±1% FS
Snow Version= ±1% FS
Resolution 1 mm
Status Normal/Tilt
Range -40 ~ 125°C
Resolution 0.1°C
Technology LoRaWAN®
Frequency CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx Power 16 dBm (868 MHz)/20 dBm (915MHz)/19 dBm (470MHz)
Sensitivity -137dBm @300bps
Mode OTAA/ABP Class A
Power On & Off NFC, Power Button (Internal)
Configuration Mobile App (via NFC)
Power Supply 2 x 9000 mAh ER26500 Li-SOCL2 Batteries
Battery Life2 > 10 years
Operating Temperature – 30°C ~ 70°C
Relative Humidity ≤95% (non-condensing)
Ingress Protection IP67
Dimension 118 × 65 × 80 mm
Material ABS + PC (Flame Retardant)
Color Black gray (C050/C100), Gray (W050/W100/S050)
Installation On the Flat Surfaces with Screws
1. This accuracy is applicable to the measuring range of 25~800cm.
2. Tested under laboratory conditions and for guideline purposes only.
$336.00 – $360.00Price range: $336.00 through $360.00